PD685 UL913 (Discontinuation Date: March 31st, 2024)

Handheld | Handheld ATEX | DMR

Highlights

diagram indicating highlights of PD685 UL913 (Discontinuation Date: March 31st, 2024)

Rugged and Reliable

Dust and waterproof, rated IP67, sustaining performance in harsh environments

Systems Connectivity

Versatile to connect with telemetry, integrate into telephony, or expand across multiple sites with Hytera XPT or DMR Tier III (licenced)

Safer Workforce

Emergency mode, priority interrupt and lone worker features are provided as standard

GPS Location

Available as an optional extra, GPS for tracking and positioning also includes man down feature

Long Battery Life

Operating time of approximately 16 hours in digital mode

Functions

Created with Sketch. GPS Positioning (Factory Option)

The built-in GPS module supports GIS applications.

Created with Sketch. Man Down (Factory Option)

When a user falls down, the radio can automatically alert others.

Created with Sketch. Pseudo Trunk

This virtual trunking feature allocates a free timeslot for urgent communications. This effectively enhances frequency efficiency and allows you to communicate in a timely manner in emergency situations.

IP67 Compliance

IP67 rated withstanding up to 1m submersion for 30 minutes or more.

Created with Sketch. Pseudo Trunking

Using pseudo-trunking, a Hytera patented technology, slots can be shared to improve capacity usage with transmissions either direct to handset or to repeater.

Created with Sketch. XPT

Hytera XPT (Extended Pseudo Trunking) enables you to use limited spectrum resources more efficiently, dynamically assigning channel resource without needing a dedicated control channel.

Created with Sketch. Emergency Mode

Raise an alarm with top priority to a base station or to other radios with the pre-programmed emergency mode, identifying the ID of the person issuing the alarm. Also receive emergency notifications.

Created with Sketch. Lone Worker

The Lone Worker feature uses a timer in the radio to measure inactivity. If the timer expires, a warning is issued, and if there is no response to that, the alarm is triggered.

Pd68 X 1

Created with Sketch. GPS

Optional, enabling location-based services to improve safety and control.

Created with Sketch. Bluetooth Audio

Optional (external adapter accessory), wireless connectivity to audio devices to improve user experience.

Created with Sketch. Man Down

Optional, the man down feature will let you know if the radio has been tilted past a certain angle. This may happen for instance if the radio user has fallen over or is unconscious or injured. The alarm will be triggered after a warning is issued to the user.

Accessories for PD685 UL913 (Discontinuation Date: March 31st, 2024)

Included as standard with PD685 UL913 (Discontinuation Date: March 31st, 2024) Included as standard with PD685 UL913 (Discontinuation Date: March 31st, 2024)

Related products that work with the PD685 UL913 (Discontinuation Date: March 31st, 2024)

Technical Specifications

General

Frequency Range
VHF1: 136-174MHz UHF1: 400-470MHz, 400-527MHz
Channel Capacity
1024
Zone Capacity
64 , each with a maximum of 256 channels
Battery Life (5-5-90 Duty Cycle)
Digital: 21 Hours @2000mAh Analog: 14.5 Hours @2000mAh
Dimensions
122 x 54 x 33 mm (2000mAh)
Weight
344g (2000mAh)
Channel Spacing
25/20/12.5kHz
Frequency Stability
±0.5 ppm
Antenna Impedance
50Ω

General

Frequency Range
Um: 400-527MHz VHF: 136-174MHz
Channel Capacity
1024
Zone Capacity
64 (each with a maximum of 256 channels)
Channel Spacing
25/20/12.5KHz
Operating Voltage
7.4V
Battery
2000mAh (Li-Ion)
Battey Life(5/5/90 Duty Cycle,High TX Power)
Analog/Digital: 14.5hours/21hours
Frequency Stability
±0.5ppm
Antenna Impedance
50Ω
Dimensions(H×W×D) mm
122 x 54 x 33
Weight
344g
Anti-explosion levels
Class I II III DIV 1 Group C-G T4

Environmental Specifications

Dust & Water Intrusion
IP67 Standard
Operating Temperature
-30℃ ~ +55℃
Storage Temperature
-40℃ ~ +85℃

Transmitter

RF Power Output
UHF HP 4W UHF LP 1W VHF HP 5W VHF LP 1W
FM Modulation
14K0F3E @ 20kHz 16K0F3E @ 25kHz 11K0F3E @ 12.5kHz
4FSK Digital Modulation
12.5KHz Data Only: 7K60FXD 12.5KHz Data & Voice: 7K60FXW
Conducted/Radiated Emission
-36dBm ≤1GHz -30dBm > 1GHz
Modulation Limiting
±2.5KHz @ 12.5KHz ±4.0KHz @ 20KHz ±5.0KHz @ 25KHz
FM Hum&Noise
40dB @ 12.5KHz 43dB @ 20KHz 45dB @ 25KHz
Adjacent Channel Power
60dB @ 12.5KHz 70dB @ 20/25KHz
Audio Response
+1 ~-3dB
Audio Distortion
≤3%
Digital Vocoder Type
AMBE+2™ or SELP
Digital Protocol
ETSI-TS102 361-1,-2,-3

Features

RRS
Telemetry
Option Board
Intrinsically Safe Option
Radio Check
Alert Call
Stun / Unstun
Remote Monitor
IP Site Connect
Roaming
Work Order
5 Tone Signalling
2 Tone Signalling
HDC1200 Signalling
DTMF (Phone Patch)
Intelligent Audio
VOX
Priority Scan
GPS SMS
Vibration
Scrambler (Analogue)
Digital Encryption
Multiple Key Encryption Decode
Multi-language Menu
Power on & off user logo programming
Voice Interrupt
No of Contacts (Conventional)
No of Contacts (Trunking)
Text Messaging
Quick Text Messages
MPT1327 / 1343 Trunking
Tier 3 Trunking
Over-the-Air Programming
Analogue Only Version
Auto Power Select

Receiver

Sensitivity(Analog)
0.3μV (12dB SIN AD) 0.22μV(Typical)(12dB SINAD) 0.4μV(20dB SINAD)
Sensitivity(Digital)
0.22μV/BER 5%
Adjacent Channel Selectivity
TIA-603: 60dB @ 12.5 KHz / 70dB @ 20&25KHz ETSI: 60dB @ 12.5 KHz / 70dB @ 20&25KHz
Spurious Response Rejection
TIA-603: 70dB @ 12.5 / 20 / 25KHz ETSI: 70dB @ 12.5 / 20 / 25KHz
Intermodulation
TIA-603: 70dB @ 12.5 / 20 / 25KHz ETSI: 65dB @ 12.5 / 20 / 25KHz
Hum&Noise
40dB @ 12.5KHz 43dB @ 20KHz 45dB @ 25KHz
Blocking
84dB
Rated Audio Power Output
0.5W
Rated Audio Distortion
≤3%
Audio Response
+1 ~-3dB
Conducted Spurious Emission
<-57dBm

GPS Specifications(For the Model with GPS)

Horizontal Position Accuracy
<5m (50% probable) <10m (95% probable)
Cold Start (Time to First Fix)
<1 minute
Hot Start (Time to First Fix)
<10 seconds
Note
Accuracy Specs are for long-term tracking(95th percentile values>5 satellites visible at a nominal-130dBm signal strength)

Environmental

Operating Temperature
-30℃~+55℃
Storage Temperature
-40℃~+85℃
ESD
IEC 61000-4-2(level 4) ±8kV(Contact) ±15kV(Air)
MIL Standard
MIL-STD-810 C/D/E/F/G
Humidity
Per MIL-STD-810 C/D/E/F/G
Dust & Water Protection
IP67
Shock & Vibration
Per MIL-STD-810 C/D/E/F/G